Brand Name : GAOGE
Model Number : GAG-BR
Certification : CE/ISO9001
Place of Origin : CHINA
MOQ : 1 set
Price : Negotation
Payment Terms : T/T, Western Union
Supply Ability : 15 sets per month
Delivery Time : 15 working days after received your payment
Packaging Details : Standard Export Wooden Case (Plywood)
Customized : Customized
Type : Walk-in Climatic Chamber
Controller : Programmable LCD Touch Screen
Humidity Range : 20%~98%Rh
Compressor : Original France Tecumseh,Germany Bizer Brand
Material : Stainless Steel
Power Supply : AC 3 Phase 380V 60/50Hz
UV Lamp Walk In Stability Climatic Test Chamber With High Low Temperature System
Description
Walk-in constant temperature and humidity chamber are suitable for large part and machinery undergone low to high, high to low temperature changing test, which can change the room size according to user's need. It applies to Patchwork type chamber, with the feature of nice looking outlook, scientific design for pipe and duct, all in one touch screen control panel and a programmable logic controller can satisfy most needs of all kinds of clients.
Specifications
Inside volume (m³) | 10 | 12 | 17.5 | 22 | 32 | 40 | 60 | |
Inner size: W*D*H(cm) | 200*250*200 | 200*300*200 | 350*250*220 | 250*400*220 | 340*240*390 | 340*240*480 | 500*200*600 | |
Performance | temperature range | R: -20ºC~150ºC; L: -40ºC~150ºC; U: -60ºC~150ºC | ||||||
Humidity | 20%~98%RH | |||||||
Temp. fluctuation | ±0.5ºC | |||||||
Temp. deviation | ±2ºC | |||||||
Humidity deviation | ±3.0%RH(>75%RH), ±5.0%RH(≤75%RH)*4 | |||||||
Heating time | 20→85ºC within 60 minute | |||||||
Cooling time | 20ºC→rated min. temperature within 60/90/120 minute | |||||||
temp. and humidity adjust method | BTHC balance adjust temperature(humidity) way. | |||||||
Chamber materials | Polyurethane foam plastics compound board(inner: stainless steel
plate; Outer: galvanized copper plate with powder coating. | |||||||
Controller | Heater | Nickel chromium alloy electrical heater | ||||||
Humidifier | Steam humidifier | |||||||
Fan | Centrifugal fan | |||||||
Refrigeration method | Mechanical compression single grade refrigerating or mechanical compression two element superposition refrigeration(water*5) | |||||||
Refrigeration compressor | full closed or semi-closed compressor | |||||||
Refrigerant | HCFC-22 or HCFC-23 | |||||||
Refrigeration heat exchanger | Finned heat exchanger | |||||||
Controller appliance | Operation interface | 10.5" 800*600 dot matrix color LCD touchscreen | ||||||
Running mode | Constant running, Program running | |||||||
Procedure memory capacity | 120 programmable programs; each program have 100 steps(paragraph), 10 cycle steps(each step have 99 cycles at most) | |||||||
Setting range | Temperature: -100ºC~300ºC ; Humidity: 0%~99.9%RH*4 | |||||||
Resolution ratio | Temperature: 0.01ºC ; Humidity: 0.1%RH*4 | |||||||
Input | PT100 | |||||||
Controlling mode | PID control | |||||||
Communication function | RS-232 interface(optional) | |||||||
Print function | Mini-digital printer(optional) | |||||||
Subsidiary Function | Alarm functions of the upper and lower limits, self diagnosis, alarm warning, power off protection, timing function(automatic starting and stopping) | |||||||
Water supply | Humidity system | Equipped with multistage filtering anti penetration water purifier(user offer tap water) or user offer distilled water*4 with resistivity not less than 500Ωm. | ||||||
Cooling recirculation water system | Water supply pressure: 0.2~0.4MPa; water temperature<=30ºC. | |||||||
Power supply | AC380±10%V 50±0.5Hz 3-phase 4-wire+protective earth line. | |||||||
Standard configurations | Electrothermal glass observation window, leading hole(80mm),
lighting lamp, accumulative timer. | |||||||
Safety device | Current circuit breaker, dry heating protector(humidifying system),
the water system protection, the fan overheating protection, compressor overprocess, overheating and overcurrent protection, open-phase protection, over temperature protection, | |||||||
Customized service | Welcome to Non-standard, Special requirements, OEM/ODM orders. |
Features
1. Large system capacity: 120 patterns*1200 steps, circulation Setting: Max. 9999 cycles, PID+SSR/SCR controller. Curves drawing, a safety device
2. RS-232/RS-485/RJ 45/Ethernet/USB communication interface.
3 .CE certification
4. Large LCD Touchscreen controller
5. SUS#304 stainless steel plate inner chamber, stainless steel plate with Powder coated exterior chamber.
6.Germany Bitzer compressor, environmental-friendly refrigerant (R404A, R23)
7. PU&fiberglass wool insulation is to make the temperature stable.
8. Large glass observation window with lamp, users can see the sample test effects directly.
Standard
1. GB11158 Technical conditions for high-temperature testing room |
2. GB10589-89 Technical conditions for low-temperature testing room |
3. GB/T10586-89 technical conditions for humidity testing room |
4. GB/T2423.1-2001 testing methods for low-temperature |
5. GB/T2423.2-2001 testing methods for high-temperature |
6. GB/T2423.3-93 technical conditions for humidity testing room |
7. GB/T2423.4-93 testing method for alternating hot and humid |
8. IEC60068-2-1.1990 testing methods for low-temperature |
9. IEC60068-2-2.1974 testing methods for high-temperature |
10. GJB150.3 High-temperature test |
11. GJB150.4 Low-temperature test |
12. GJB150.9 muggy test |
13. GB/T2423.22 temperature test |
![]() |
UV Lamp Walk In Stability Climatic Test Chamber With High Low Temperature System Images |